• Universal AC input / Full range
• Protections: SC / OL / OV
• Cooling by free air convection
• LED indicator for power on
• 100% full load burn-in test
• All using 105°C long life electrolytic capacitors
• Withstand 300 VAC surge input for 5 seconds
• High operating temperature up to 70° C
• Withstand 5G vibration test
• High efficiency, long life and high reliability
• Approvals: UL / TUV
• 3 year warranty
• AC input voltage range: 115/230 VAC selectable by switch
• C inrush current: Cold start, 50A @ 230VAC
• DC adjustment range: ±10% by potential meter for single output; CH1: -5% ~ +10% by potential meter for multiple output
• Over load protection: 110% ~ 150% hiccup mode, auto-recovery
• Over voltage protection: 115% ~ 135% rated output voltage, hiccup mode, auto recovery
• Withstand voltage: I/P~O/P: 3KVAC, I/P~FG: 1.5KVAC, OP/-FG: 0.5KVAC
• Working temperature: -25 ~ 70° C (refer to output derating curve)
• Setup, rise, hold up time: 800ms, 20ms, 20ms at full load and 230VAC
• Safety standards: UL60950-1, TUV EN60950-1 approved
• EMC standards: EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61000-6-2 (EN50082-2) heavy industrial level criteria A
•
Mean Well RT-50 Specifications and FootprintMean Well RT-50 Model Specs
| Model # | Output | Tol. | R&N | Effi. | Max. |
|---|
| RT-50B | 5V, 0.5~6A 12V, 0.2~1.5A | ±2% ±6% | 80mV 120mV | 74% | 46W |
| RT-50C | 5V, 0.5~6A 15V, 0.2~1.5A -15V, 0~1A | ±2% ±6% ±2% | 80mV 120mV 80mV | 75% | 50W |
| RT-50D | 5V, 0.5~6A 12V, 0.2~1.5A 24V, 0.1~1A | ±2% ±6% +7%, -5% | 80mV 120mV 180mV | 79% | 63W |
RT-50 Model #: